How to become a Chief Engineer in Australia

The site’s technical authority: owns its procedures, reviews its changes, finds the root causes of failures, and accepts new plant into service.

What the role does

The site’s technical authority, between the shifts and the facilities manager: procedures, change review, root causes, capacity and the technical depth behind the shifts. Witnesses commissioning tests and accepts plant into service. Reached from Lead or Supervisor or, with lead or senior specialist experience, from a specialist track.

What a shift looks like

Office hours, with on-call. Change reviews, method statements, investigations, capacity planning, and witnessing commissioning tests.

What employers call it

  • Technical Services Manager (colocation and wholesale)
  • Facilities Senior Engineer (FM and service contractor)

Skills

The level the role needs in each, on FacilityVR’s five levels from Aware to Authority.

Safe isolation

  • Authorise isolations Leads others

Procedures and documents

  • Work within change management Leads others
  • Write and review a MOP Leads others

Leadership

  • Coach and assess others Leads others
  • Find root causes and learn from incidents Leads others

LV distribution

  • AI load swings and how they are smoothed Leads others
  • Trace the power path and its redundancy Leads others

MV switching

  • Read MV systems and their protection Leads others
  • Write and carry out a switching programme Independent, desirable

Cooling plant

  • Psychrometrics and the thermal envelope Leads others

Monitoring and response

  • Read trends and capacity Leads others

Commissioning

  • Accept capacity in phases Leads others
  • Check operational readiness at handover Leads others
  • Work in a site that is part live and part under construction Leads others
  • Run functional performance tests Independent
  • Take part in integrated systems testing Independent

Site safety

  • Assess risk and plan safe work Leads others

Liquid cooling

  • Know who owns each part of the loop Leads others, desirable
  • Fill, flush and vent a TCS loop Independent, desirable
  • Liquid-cooled IT and its loops Independent, desirable

Power transfer and generation

  • Coordinate load changes with the site plant or utility Leads others
  • Prime and behind-the-meter power Leads others

Emergency response

  • Recognise and report a suspected cyber incident Independent

Licences and credentials

Not legal advice: check with the regulator for your state.

Nationally recognised units

Units of competency that line up with what the role asks, as training.gov.au publishes them.

  • UEECD0016 Document and apply measures to control WHS risks associated with electrotechnology work
  • UEPOPS124 Perform switching to a switching program

Ways in and ways on

From another data centre role

Where it leads